Corona Treatment Power Supplies

The P6000 Series features IGBT (Insulated Gate Bi-Polar Transistors) technology providing the most versatile corona treater power supply on the market today. This compact unit incorporates a circuit design that enables instant and efficient power. The P6000 automatically adjusts itself to match into any electrode style or dielectric material and offers the operator better than 4 to 1 load matching.

The versatility of the P6000 Series Corona Treater Power Supply provides for a nominal turn down ratio of 20 to 1, allowing the operator to precisely turn the power up or down to achieve the desired treat level. The specially designed power measurement circuit guarantees that the power specified is the power being delivered and the feedback circuit automatically maintains constant output power regardless of minor changes in load conditions, humidity and temperature.

Benefits of the P6000 Series Power Supply

  • Easy to install
  • Accurate output power
  • Small, compact design
  • Low maintenance
  • Superior “load match” for a wide range of applications
  • Best available “turn down ratio” in the industry
  • Economical design, improved cost savings
  • User friendly “touch” control pad

Features of the P6000 Series Power Supply

  • Start/Stop contactor for safe, dependable operation
  • CE or ETL certified
  • Digital LED displays Power, Voltage, Current, Frequency
  • Microprocessor controlled
  • Power supply diagnostic indicators
  • Loss of treatment indicator
  • Humidity compensation control

What is Load Matching?
Load matching is the ability of a power supply to provide full output power to various load conditions. Typically, these
changes in load are caused by adjusting electrodes to match different treat widths, although changes from one roll
covering type to another or to different electrode sizes will also change load conditions.

What is Turn Down Ratio?
Turn down ratio is the ability of a power supply to reduce the output power to the bare minimum and still produce an
even corona across the air gap. This is critical when a variety of different materials are to be treated or when proportional
speed adjustments are automatically made.

How does this relate to Pillar’s P6000 Series Power Supply?
Pillar’s P6000 has been designed to provide the widest range of flexibility to its user. Setting it in a class by itself, the
P6000 load matching ability is capable of providing a range typical of variable frequency power supplies. The P6000
turn down ratio is unequaled by any other high frequency power supplies on the market.

Power Supply Specifications
HV Output
Transformer
(Oil-Filled Type)
Size
(kW)
Height
(mm)
Width
(mm)
Depth
(mm)
Weight
(Kg)
Power Input
(Volts AC/
Phase)
Weight
(Kg)
Dimensions
H/W/D
(mm)
0.5
406
406
224
20
230/single
34
260/292/362
0.75
406
406
224
20
230/single
34
260/292/362
1
406
406
224
20
230/single
34
260/292/362
1.5
406
406
224
20
230/single
34
260/292/362
2
406
406
224
20
230/single
34
260/292/362
3.0
508
406
280
27
230/three
34
260/292/362
3.5
508
406
280
27
230/three
34
260/292/362
5
762
5/750
329
68
460/three
40
311/317/412
7.5
762
750
329
68
460/three
40
311/317/412
10
762
750
329
68
460/three
40
311/317/412
15
762
750
329
68
460/three
57
381/368/413
20
914
1054
329
125
460/three
103
470/368/516
25
914
1054
329
125
460/three
103
470/368/516
30
914
1054
329
125
460/three
103
470/368/516

 

Watt Density Control (Optional)


Total Function Control (Optional)

Options Available

  • Watt Density Control
  • Skip Treat
  • Proportional Speed Control
  • Computer Interface
  • Connection Cable Set
  • Flex High Voltage Cable
  • Input Transformer
  • P6000 Water Cooling
  • P6000 Added Fan Cooling
  • HV Transformer Mount
  • HV Switch Box
  • Power, Frequency, Amps,
  • Volts Data Logging
  • Remote Control Station
  • Remote Operator Panel
  • Total Function Control (TFC)
  • TFC with CAN Bus
  • TFC with Profibus


Additional Specifications

Construction
Wall mounted cabinet with front access door

Power Input
230 VAC (+/- 10%), 1-phase, 50/60 Hz on
0.5 kW-3.0 kW
400 VAC (+/- 10%), 3-phase, 50/60 Hz on
3.0 kW-3.5 kW

Power Output (kW)
0.5, 0.75, 1.0, 1.5, 2.0, 2.5, 3.5, 5.0, 7.5,
10.0, 15.0, 20.0, 25.0, 30.0

Power Control
Microprocessor Based Manual Power Control

Technology
Insulated Gate Bi-Polar Transistor (IGBT)

Panel Meter
3-Digit LED Display

Controls
Start/Stop push buttons, touch pad

Output Transformer
Oil-Filled, Convection Cooled, Multiple Tap capable
of matching into various load conditions

 